Our reactors and line traps are custom designed and manufactured to meet all IEEE/ANSI and IEC Standards, as well as any other specific standards required by our customers.
Conductors used in dry-type air core reactors and line traps are custom-designed. Size and insulation types are specifically made according customers’ unique specifications – each designed to ensure maximum insulation integrity and cost effectiveness.
Our horizontal and vertical structured epoxy-impregnated fiberglass encapsulation provides superior mechanical strength, minimizing both reactor vibration and sound level.
Conductor insulation is custom-designed to ensure coil strength and integrity. This not only minimizes turn-to-turn voltage stress levels, it also prevents moisture ingress and improves overall insulation reliability.
Current-carrying components are constructed of aluminum, and individual conductors are crimped and welded together. All conductor terminations are then welded to the aluminum bus bars, forming the top and bottom spider arms of the reactor.
To ensure reactor safety and longevity, all materials are carefully selected and undergo significant testing before and during the manufacturing process. Our reactors are designed to operate at low temperatures, allowing for overload capacity and ensuring the longest-possible service life.
We can provide steel or fiberglass support structures, raising reactors above the ground. This ensures proper magnetic clearance between the ground and the reactor and it also provides safe personnel clearance at ground level while energized.
Finally, our custom-engineered support systems are designed to reinforce the mechanical structure of the reactor without significant weight increases, reducing both the overall dimensions and the number of insulators required.
As you can see, we are very well established (and growing further) in the development of all types of inductors/reactors. We welcome discussions, inquiries, and orders from any location worldwide.
Reactors | Line Traps |
---|---|
Customer Name* | Customer Name* |
Shipping Address c/w ZipCode* | Shipping Address c/w ZipCode* |
Quantity* | Quantity* |
RatedContinuousCurrent (A)* | RatedContinuousCurrent (A)* |
System Voltage (kV)* | System Voltage (kV)* |
Rated Thermal Short-Time Current (kA/s)* | Rated Thermal Short-Time Current (kA/s)* |
Rated Impedance or Inductance (ohms or mH)* | Rated Main Coil Inductance (mH)* |
Power Frequency (Hz)* | Power Frequency (Hz)* |
Applicable Standard* | Applicable Standard* |
Application: Seriesor Shunt | Type of Tuning— Single or Double or Wideband* |
Harmonic Currents (A/Hz) | Fixed or Adjustable Tun ing Capability* |
Maximum Continuous Overload Current (A) | Bandwidth Frequencies ( Hz)* |
Mechanical Short-Tim e Current (kA/pe*) | Minimum Blocking Impedance/ReSstance (ohms)* |
Average Ambient Temperature (oF or oC) | Mounting — Vertical or Horizontal* |
Maximum Ambient Temperature (oF or oC) | Average Ambient Temperature (oF or oC) |
Site Altitude (ft or m) | Maxi mum Ambient Temperature (oF or oC) |
Seismic Level (G) | Site Altitude (ft or m) |
BIL Across Reactor (kV) | Seismic Level (G) |
BIL Reactor to Ground (kV) | Special Environmental Considerations (if any) |
Maximum Noise Level (dBA) | Special Technical Requirements ( if any) |
Special Environmental Considerations (if any) | |
Special Technical Requirements (if any) |
Model | Equipment rated voltage (kV) | Highest voltage for equipment (kV) | Rated inductance (mH) | Rated DC current (A) | Maximum contin- uous DC (A) | Total harm- onic current (A) | Loss (kW) | Transient fault current (kA) | Single pole coil lightning impulse voltage (kV) | Insulator lightning impulse voltage (kV) | Outer dia- meter (m) | Height (m) | Weight (kg) |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
PKDGKL-800-5000-50 | 800 | 816 | 50 | 5000.00 | 5046 | 309 | 345.10 | 40 | 2100 | 1950 | 4.71 | 4.09 | 65502 |
PKDGKL-800-5000-75 | 800 | 816 | 75 | 5000.00 | 5046 | 309 | 426.47 | 40 | 2100 | 1950 | 4.71 | 4.19 | 79750 |
PKDGKL-800-6250-50 | 800 | 816 | 50 | 6250.00 | 6296 | 386 | 431.09 | 40 | 2100 | 1950 | 5.22 | 4.35 | 94092 |
PKDGKL-800-6250-75 | 800 | 816 | 75 | 6250.00 | 6296 | 386 | 534.67 | 40 | 2100 | 1950 | 5.81 | 4.63 | 122535 |
PKDGKL-1100-5000-50 | 1100 | 1120 | 50 | 5000.00 | 5046 | 309 | 348.45 | 40 | 2600 | 2580 | 5.21 | 4.09 | 76072 |
PKDGKL-1100-5455-75 | 1100 | 1120 | 75 | 5455.00 | 5523 | 230 | 390.00 | 40 | 2600 | 2580 | 5.7 | 4.6 | 105000 |
PKDGKL-1100-6250-50 | 1100 | 1120 | 50 | 6250.00 | 6296 | 386 | 435.27 | 40 | 2600 | 2580 | 5.62 | 4.35 | 94910 |
PKDGKL-1100-6250-75 | 1100 | 1120 | 75 | 6250.00 | 6296 | 386 | 539.86 | 40 | 2600 | 2580 | 5.81 | 4.63 | 123601 |
Model | Systemrated volt-age (kV) | Equipment rated voltage (kV) | highest voltage for equip-ment (kV) | Rated induct-ance (mH) | Rated react-Ance (Ω) | Rated current (A) | Power Rating (kVAr) | Loss (kW) | Short circuit current/ duration (kA/s) | Coil lightning impulse voltage (kV) | Insulator lightning impulse voltage (kV) | Outer diameter (m) | Height (m) | Weight (kg) |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
XKDGKL-500-3600-33.43 | 500 | 500 | 550 | 33.43 | 10.50 | 3600 | 136090 | 307.42 | 40/4 | 1550 | 1550 | 3.77 | 4.34 | 28434 |
XKDGKL-500-4000-33.43 | 500 | 500 | 550 | 33.43 | 10.50 | 4000 | 168012 | 346.41 | 40/4 | 1550 | 1550 | 3.95 | 4.30 | 32062 |
XKDGKL-500-2400-38.2 | 500 | 500 | 550 | 33.43 | 12.00 | 2400 | 69116 | 186.15 | 40/4 | 1550 | 1550 | 3.41 | 4.31 | 19611 |
XKDGKL-500-3000-38.2 | 500 | 500 | 550 | 38.20 | 12.00 | 3000 | 107994 | 266.07 | 40/4 | 1550 | 1550 | 3.69 | 4.30 | 24623 |
XKDGKL-500-3600-38.2 | 500 | 500 | 550 | 38.20 | 12.00 | 3600 | 155511 | 322.52 | 40/4 | 1550 | 1550 | 3.94 | 4.30 | 30590 |
XKDGKL-500-4000-3.82 | 500 | 500 | 550 | 38.20 | 12.00 | 4000 | 191989 | 365.66 | 40/4 | 1550 | 1550 | 4.12 | 4.31 | 34639 |
XKDGKL-500-2400-44.56 | 500 | 500 | 550 | 44.56 | 14.00 | 2400 | 80634 | 202.55 | 40/4 | 1550 | 1550 | 3.62 | 4.31 | 21232 |
XKDGKL-500-2800-44.56 | 500 | 500 | 550 | 44.56 | 14.00 | 2800 | 109752 | 239.95 | 40/4 | 1550 | 1550 | 7.76 | 4.34 | 25905 |
XKDGKL-500-3000-44.56 | 500 | 500 | 550 | 44.56 | 14.00 | 3000 | 125990 | 287.70 | 40/4 | 1550 | 1550 | 3.90 | 4.33 | 26984 |
XKDGKL-500-3600-44.56 | 500 | 500 | 550 | 44.56 | 14.00 | 3600 | 181426 | 343.49 | 40/4 | 1550 | 1550 | 4.16 | 4.30 | 34359 |
XKDGKL-500-4000-44.56 | 500 | 500 | 550 | 44.56 | 14.00 | 4000 | 223983 | 394.94 | 40/4 | 1550 | 1550 | 4.31 | 4.34 | 37926 |
XKDGKL-500-2400-57.3 | 500 | 500 | 550 | 57.30 | 18.00 | 2400 | 103688 | 223.06 | 40/4 | 1550 | 1550 | 3.96 | 4.32 | 27721 |
XKDGKL-500-3000-57.3 | 500 | 500 | 550 | 57.30 | 18.00 | 3000 | 162012 | 318.93 | 40/4 | 1550 | 1550 | 4.32 | 4.34 | 31688 |
XKDGKL-500-3600-57.3 | 500 | 500 | 550 | 57.30 | 18.00 | 3600 | 233297 | 390.68 | 40/4 | 1550 | 1550 | 4.58 | 4.34 | 39188 |
XKDGKL-500-4000-57.3 | 500 | 500 | 550 | 57.30 | 18.00 | 4000 | 288021 | 444.09 | 40/4 | 1550 | 1550 | 4.74 | 4.34 | 44030 |
XKDGKL-500-2400-66.85 | 500 | 500 | 550 | 66.85 | 21.00 | 2400 | 120969 | 240.12 | 40/4 | 1550 | 1550 | 4.27 | 4.33 | 28203 |
XKDGKL-500-3000-66.85 | 500 | 500 | 550 | 66.85 | 21.00 | 3000 | 189014 | 335.88 | 40/4 | 1550 | 1550 | 4.54 | 4.34 | 35169 |